| | 4-Square
Vertical Array

| This high performance 4-square array controller uses the
new Lahlum method of phasing and power distribution. This system
is the most accurate method of obtaining the gain and deep backward
pattern nulls. This method uses discreet LC networks just as any broadcast
array would use, to accomplish the delays and magnitude. You can read all
about it in the upcoming release of ON4UN's "Low Band DXing" book in May
2005 published by the ARRL. Until then please review in our
manuals section. |
Features


Vacuum caps - Latest version.
Specifications:
|
Construction
|
Aluminum Box, weather seals, Teflon connectors, RF
sealed
|
|
Power
|
5 KW CW / 10 KW PEP
|
|
VSWR
|
Adjustable for 1:1 perfect match – No dump load
|
|
Gain
|
5.5 dB over single vertical 6.6 dB (optimized)
|
|
Directions
|
4 directions with an added Omni-directional feature
|
|
Electronic phasing
|
LC network (Lahlum) and phase line
|
|
Phasing Options
|
Quadrature 0, -90, -180 or Optimized 0, -124,-224 9 adjustable by user
|
|
Capacitors in networks
|
True temperature stable high current RF capacitors
|
|
Weight and size
|
9 lbs 13' X 6" X 5" (relay box)
|

John Devoldere, ON4UN author of "Low Band DXing" testing the
array controller in our lab.