UNI-CNTL Manual

 

Material on this website:  copyright 1997-2008. It may be printed for your personal use but may not be used for commercial purposes, copied, or altered and posted on other websites

Array Solutions
350 Gloria Rd.
Sunnyvale,
TX 75182

Phone
(972) 203-2008
Fax
(972) 203-8811

Email Us

Version 1

Support for all products excluding StackMaster and has 6 output relays

Version 2

Support for all products including StackMaster and has 11 output relays

Features include

bulletPushbutton with LED indicators
bulletFront panel ON/OFF switch
bulletRelays drive to the outside world and isolate unit from surges
bulletTR or PTT input to prevent accidental hot switching of relays
bulletINHIBIT function which will inhibit the transmitter while relays are settling
bulletAbility to program from push buttons at any time a T/R split of any antennas
bulletEasy to wire DB15 jack which you can remove to protect device from lightning damage
bulletCircuit board jumpers allow easy configuration of controller
bulletExtensive protection of circuitry and software watchdog built into unit for reliablity

Description

Main function

Universal controller  controls of all Array Solution's Antenna switches

bulletStack Master (this relay box require StackMaster controller version 2
bulletStack Match (also with N2NU's BOP modification is supported)
bulletFour square
bulletTriangle Vertical Array
bulletDouble Vertical Array
bulletRatPak
bulletSixPak (one side per controller)

Relay box is selected by 3 configuration jumpers on board before controller is powered.

Jumpers

There are several jumpers on the main board:

1. Output level jumpers – Output level is determined by jumper located on board near the relays upper right corner of the board. The default position (positive) is appropriate for all Array Solutions products internal power source. Many users will want to use the EXT (external voltage source) jumper position to allow them to provide an external voltage source to the DB15 connector on the back. This will provide isolation between controller and the relay box outside as well as allowing the user to run higher voltage to the outside world to compensate for very long cable runs. Remember to connect the device being driven’s ground return to Pin 15 of the DB15 or directly to the negative side of the external power supply.

 

The Default position is INT (relay box will be powered from controller). If you move both jumpers to position EXT, controller will be galvanic separated from relay box (for maximal immunity). Don't forget attach external power into DB15 (see chart below). If you move only top jumper (near the connector DB15) to EXT position, unit will share GND, but relay box will be still driven by external positive voltage. (For example if you need more than 24V driving power). You will need to place the external power supply ground to the internal ground pin 13 or 15 in this mode.

2. Relay box personality jumpers -Three jumpers located on bottom right position determine controlled relay box. All open is Stack Master, etc. You must reset unit (OFF-ON) if you change these jumpers. The Array Solutions products described below give the settings for these jumpers.

 

Power limits

Input power: 13.8 – 24V DC

You can power unit from 13.8V to 24V. Output voltage to relay box will be approximately 1V less than the input voltage when using internal power to drive them. You need not connect external power if you want power relay box higher than 13.8 V. Do not exceed 24V DC or you will blow the regulators on board.

Current consumption: 150mA

150mA is minimal consumption without any relay switched on. Maximal consumption without relay box is 330mA (7 relays on for StackMaster).

RelayBox maximal consumption : 700mA

Maximal relay box current should not exceed 700mA when using internal power for output drive

Using external power supply for output drive should not exceed 500 ma per relay being driven.

This you will never do with Array Solutions products all relays are either 40, 100, or 120 ma depending on the product.

 

Integrated protection to make this controller reliable

1.Reverse voltage input protection

2.Over current protection (1.2A) Not a classic fuse, Polyswitch is used (re-settable fuse)

3.Output short-circuit protection

4.PTT input over voltage protections

5.Program hook-up protection (watchdog)

 