• AS-302N - 3kW CW / 5 kW PEP Coaxial Lightning Arrestor, N-type connectors, 1 to 500 MHz

AS-302N - 3 kW CW / 5 kW PEP Coaxial Lightning Arrestor, N-type connectors, 1 to 500 MHz.

AS-300 Series arrestors are known for their reliability and performance.  They feature easy mounting to plates, ground rods with our stacking bracket and also a convenient screw lug. The stacking bracket can be used on plates as well to save precious room in arrestor enclosures.

·               Available in SO-239, Type-N, and 7/16 DIN connectors

·               DC blocked, DC pass is available as a custom option

·               Unique static bleed system with a UL approved Gas Discharge Tube, also ITU K 12 tested.

·            This system usually prevents the GDT from ever firing unless a direct hit is taken. 

·            Saves your radio from static build up on large antennas.

·               Models available for 3 kW, 5 kW, 10 kW and higher, details on website. Lower power available.

·               FM low power broadcast model AS-303D FM 

·               Model AS-309H high-power single wire or ladder line arrestor, also DC block with static bleed

·               Control line Arrestors for 8, 12, and 16 wires – 65V sparkover.



AS-302 sweep up to almost 900 MHz. This unit was specially tuned. We support specifications up to 500 MHz.

These devices are used for protection of Radio Equipment attached to antennas.  They will protect from sand, rain, snow static buildup on antennas and feed lines which can damage sensitive radio equipment. They also will protect against damage from nearby and overhead lightning strikes.  And can mitigate damage to radios or large damage to other equipment from occurring inside buildings, enclosures, and homes.



Based on the design by  Industrial Communications Engineers (ICE) 300 Series coaxial arrestors, these arrestors have been improved in performance, packaging, and mounting hardware. These arrestors are DC blocked and include static and DC discharge capability just like the famous ICE arrestors. They also include  1200V rated Gas Discharge Tubes (GDT) which can be replaced with simple tools.  Due to the static bleed inductor inside the arrestors not only does it help to keep the tube from firing extending the life of the GDT, but by virtue of bleeding off static that is charging the coaxial cable it eliminates cable discharge noise from the sensitive receiver which can lower the noise level heard.

The enclosures are machined aluminum small blocks which have convenient removable bracket to screw the device to a plate.  We have also developed a mounting bracket system which can be purchased as an accessory to mount directly to ground rods, or plates inside enclosures, or a wall plate located at a coaxial cable entrance.

Features:

  • Easy Installation, due to the flange with holes to allow screwing it to a plate, the #8x32 stainless screw mount included, and the optional AS-300-SB Stacking bracket system
  • Ratings: 3 kW, 5 kW, and other values available depending on GDT used
  • Weather and water tight heavy duty enclosures using Stainless steel hardware
  • Safety rated and tested GDT
  • Components are easily replaced


Specifications:

  • Dimensions  2" x 2"x 1.5"inches (50.8 mm x 50.8 mm x 38.1 mm), connector to connector 3.25" (82 mm)
  • Weight 0.4 lb (0.2 kg)
  • Frequency range: 1 to 500 MHz 
  • VSWR under 1.2:1
  • Unique static bleed protection system (see manual)
  • Return Loss: Typically 40 dB
  • 50 ohms (can be used in 75 ohm systems)
  • Insertion Loss (S21) 0.02 dB or less
  • Power Ratings: 3 kW continuous @ 2:1 VSWR, 5 kW @ 1.2:1 VSWR
  • GDT Devices certified to UL497B and UL1449
  • Halogen free
  • Devices tested per ITU K.12 recommendations
  • Non radioactive materials
  • DC spark-over voltage: 600 V, 800 V or 1200 V Depending on GDT installed.
           
  • 10 operations 8/20 μs 5 kA minimum
  • 1 operation 8/20 μs 10 kA minimum
  • Max. follow current during one voltage half cycle at 50 Hz 200 A
  • Insulation resistance at 100 V DC > 10 GΩ
  • Capacitance at 50 MHz < 1 pF
  • Operation and storage temperature -40°C  to +90°C (-40°F to 194°F )
  • Climatic category (IEC 60068-1) 40/ 90/ 2

NOTE: Replacement GDT (1200V) are available CLICK HERE

AS-302 and AS-303 Manual, click here

See more about our ample selection of arrestors, click here

AS-302N - 3kW CW / 5 kW PEP Coaxial Lightning Arrestor, N-type connectors, 1 to 500 MHz

  • $84.00


Related Products

AS-302U - 3 kW CW / 5 kW PEP Coaxial Lightning Arrestor, SO-239 connectors, 1 to 500 MHz

AS-302U - 3 kW CW / 5 kW PEP Coaxial Lightning Arrestor, SO-239 connectors, 1 to 500 MHz

AS-302U - 3 kW CW / 5 kW PEP Coaxial Lightning Arrestor, SO-239 type connectors, 1 to 500 MHz.AS-300..

$75.00

AS-303U - 3 kW CW / 5 kW PEP Coaxial Lightning Arrestor, SO-239 connectors, 1 to 70 MHz

AS-303U - 3 kW CW / 5 kW PEP Coaxial Lightning Arrestor, SO-239 connectors, 1 to 70 MHz

AS-303U - 3 kW CW / 5 kW PEP Coaxial Lightning Arrestor, SO-239 connectors, 1 to 70 MHz.AS-300 Serie..

$70.00

AS-303N - 3 kW CW / 5 kW PEP Coaxial Lightning Arrestor, N-type connectors, 1 to 70 MHz

AS-303N - 3 kW CW / 5 kW PEP Coaxial Lightning Arrestor, N-type connectors, 1 to 70 MHz

AS-303N - 3 kW CW / 5 kW PEP Coaxial Lightning Arrestor, Type "N" connectors, 1 to 70 MHz.AS-300 Ser..

$77.00

AS-300-SB - AS-300 series (302U, 302N, 303U, 303N) Stacking Bracket with ground rod adapter

AS-300-SB - AS-300 series (302U, 302N, 303U, 303N) Stacking Bracket with ground rod adapter

AS-300-SB - Stacking Bracket for the AS-300 series arrestors, with ground rod adapt..

$34.00

AS-xSP MOV-1  1 Assembly, Replacement parts for inside AS-8SP, AS-12SP, AS-16SP arrestors

AS-xSP MOV-1  1 Assembly, Replacement parts for inside AS-8SP, AS-12SP, AS-16SP arrestors

AS-xSP - Replacement MOV and Capacitor Assembly for the AS-8SP, AS-12SP and AS-16SP arrestors. &n..

$7.00

LP2201-2800 - M-F ground lug N-type, 6400 W (@ 1:1 SWR)

LP2201-2800 - M-F ground lug N-type, 6400 W (@ 1:1 SWR)

  LP2201-2800 Surge Arrestor, M-F ground lug N-type connector, 3600 W      ..

$130.00

LP2203-2800 - F-F ground lug N-type, 6400 W (@ 1:1 SWR)

LP2203-2800 - F-F ground lug N-type, 6400 W (@ 1:1 SWR)

LP2203-2800 surge arrestor, F-F ground lug N-type, 3600 W           &n..

$125.00

LP2204-2800 - F-F Bulkhead N-type, 6400 W (@ 1:1 SWR)

LP2204-2800 - F-F Bulkhead N-type, 6400 W (@ 1:1 SWR)

LP2204-2800  Surge arrestor, F-F Bulkhead N-type, 3600 W           &nb..

$120.00

Tags: arrestors, surge arrestor, coaxial arrestor, coaxial lightning arrestor, surge supressor, as302u, as-302u, lightning arrestor, as303, as-302n, as302N, as-303, AS-302n, as-302n, AS-302N, AS-302U, AS-302, AS302U, as302u